3.1  Applications
Type of pressure: Relative pressure

Pressure resistance
Bursting
Measuring range
(max. permissible
pressure
pressure) *)
bar
psi
bar
psi
bar
psi
Pressure sensors with G¼ internal thread
PN2160
0...600
0…8700
800
11580
2500 36250
PN2070
0...400
0…5800
800
11580
1700 24650
PN2071
0...250
0…3625
500
7250
1200 17400
UK
PN2092**
0...100
0…1450
300
4350
650
9400
PN2093**
-1...25
-14.5…362.5
150
2175
350
5075
PN2094**
-1...10
-14.6…145
75
1087
150
2175
PN2096
-0.125...2.5 -1.8…36.25
20
290
50
725
mbar
psi
mbar
psi
mbar
psi
PN2099
-1000...1000 -14.5...14.5
20000
290
50000
725
PN2097
-50...1000 -0.72…14.5
10000
145
30000
450
PN2169
-500...500
-7.26...7.26
10000
145
30000
450
PN2098
-12.5...250
-10000
-30000
-Pressure sensors with G¼ external thread
PN2560
0...600
0…8700
800
11580
2500 36250
PN2570
0...400
0…5800
800
11580
1700 24650
PN2571
0...250
0…3625
500
7250
1200 17400
PN2592**
0...100
0…1450
300
4350
650
9400
PN2593**
-1...25
-14.5…362.5
150
2175
350
5075
PN2594**
-1...10
-14.6…145
75
1087
150
2175
PN2596
-1.25...2.5 -1.8…36.25
20
290
50
725
mbar
psi
mbar
psi
mbar
psi
PN2599
-1000...1000 -14.5...14.5
20000
290
50000
725
PN2597
-50...1000 -0.72…14.5
10000
145
30000
450
PN2569
-500...500
-7.26...7.26
10000
145
30000
450
PN2598
-12.5...250
-10000
-30000
-*) With static overload pressure or max. 100 million pressure cycles.

**) Use
devices with a measuring range ≥ 250 bar for gas applications > 25 bar!
For a measuring range of 0...100 bar the PN7 series (PN7072 or PN7572) with 2 switch
points can be used for gas applications.
MPa = (measured value in bar) ÷ 10
kPa = (measured value in bar) x 100
Order
number